Welcome to Suzhou Dingluxuan Sensor Technology Co., Ltd.

Power Station Thermocouple / RTD

PRODUCT DETAIL

Home/ Products/ Power Station Thermocouple / RTD

Power Station Thermocouple / RTD

Overview

Power station thermocouple (RTD)

Applications

Tel: 0512-57892201  Mobile: 13451695112

Key Features

  • Insulation Resistance at Room Temperature
  • Measuring range & tolerance

Technical Specifications

Specifically designed for power stations, it meets the temperature measurement requirements of 300 000 kW and 600 000 kW generator sets and their auxiliary equipment. It directly measures liquids, steam and gaseous media as well as solid surfaces within -100 °C to 800 °C in various production processes.

Operating Principle

The electrodes of a thermocouple are made of two different conductor materials. When a temperature difference exists between the measuring junction and the reference junction, a thermoelectric EMF is generated, and the indicating instrument displays the temperature value corresponding to that EMF.

The resistance thermometer measures temperature by means of the characteristic that the resistance of a substance changes with temperature. When the resistance value changes, the indicating instrument displays the temperature value corresponding to that resistance.

Main Technical Specifications

Applicable standards

OIEC584

OIEC751

OGB/T16839-1997

OJB/T8622-1997

OJB/T8623-1997

For thermocouples, at an ambient temperature of 20±15 °C, relative humidity not exceeding 80%, and a test voltage of 500±50 V (DC), the insulation resistance between the electrode and the outer sheath shall be ≥ 100 MΩ·m.

For RTDs, at an ambient temperature of 15–35 °C, relative humidity not exceeding 80%, and a test voltage of 10–100 V (DC), the insulation resistance between the electrode and the outer sheath shall be ≥ 100 MΩ.

Model Graduation No. Tolerance Class
I Ⅱ
Tolerance value Measuring RangeC Tolerance value Measuring RangeC
WRN K ±1.5℃ -40~375 ±2.5℃ -40~333
±0.004H 375~1000 ±0.0075lH 333~1200
WRE E ±1.5℃ -40~375 ±2.5℃ -40~333
±0.004H 375~800 ±0.0075lH 333~900

○Thermocouple

○RTD (Resistance Thermometer)

Model Graduation No. Measuring Range Accuracy Class Permissible deviation
WZP Pt100 -200~500 Class A ±(0.15+0.002,t,)
Class B ±(0.30+0.005,t,)
WZC Cu50 Cu100 -50~150 ±(0.30+0.006,t,)

Note: t is the absolute value of the temperature measured by the sensing element

Ordering & Inquiry

For selection guidance, specification confirmation or quotation, please call 0512-57892201, Mobile 13451695112, or submit an online order. Suzhou Dingluxuan Sensor Technology Co., Ltd. provides a complete matching service from temperature sensing elements to complementary ceramic insulation parts.

No selectable data could be extracted for this product. Please check “Product Specifications” or contact us for guidance.

To order this product or get selection guidance, please call +86 512-57892201 or submit an online order.

Inquire About This Product → Back to Products

Dingluxuan Sensor Technology

Design, manufacturing and sales of temperature, pressure and humidity sensors, instruments and ceramic products — delivering integrated temperature-measurement and control solutions.

Products

Products

Applications

Applications

Contact Us

Contact
No. 828 Xueyuan Road, Bacheng Town, Kunshan City, Jiangsu, China
Tel
0512-57892201
Mobile: 13451695112
Email: yanghui@dingluxuan.com
Copyright©2017-2026  Suzhou Dingluxuan Sensor Technology Co., Ltd.   苏ICP备17068273号-1
中文EN
中文EN
×

Need help with selection or a quote?

Send us your operating conditions and get model recommendations plus a quote within 1 business day.

Inquire Online → Or call +86 512-57892201