Assembled RTD
The WZ□ assembled RTD is used together with indicating instruments and can measure the temperature of liquids, gaseous media and solid surfaces in the range of -200 to 650 °C. It is widely used in aerospace, atomic energy, petroleum, chemical, power, textile, food and other sectors as well as in science and technology. The assembled RTD usually consists of a sensing element, an outer protection tube, a terminal head and mounting fittings.
Tel: 0512-57892201 Mobile: 13451695112
| Code Segment | Meaning & Options | Value in This Example |
|---|---|---|
| W | Temperature instrument | W |
| Z | RTD (Resistance Thermometer) | Z |
| P | Sensing Element Material (P:Platinum C:Copper) | P |
| ₂ | No. of Sensing Elements (Unmarked: single ₂: dual) | ₂ |
| 2 | Mounting Fitting (1:Without fixing device 2:Fixed thread 3:Loose flange 4:Fixed flange 5:Swivel union 6:Tapered fixed thread 7:Straight union) | 2 |
| 3 | Terminal Head Type (0:Simplified 2:Splash-proof 3:Waterproof 4:Flameproof) | 3 |
| 0 | Protection Tube O.D. (0:φ16mm 1:φ12mm) | 0 |
| Class A | Accuracy Class (Class A / Class B) | Class A |
| 650×500 | Total Length × Insertion Length | 650×500 |
| B | Protection Tube Material (B:1Cr18Ni9Ti) | B |
The RTD is designed and manufactured on the principle that the resistance of a substance changes with temperature. The sensing part of an RTD is made of metal wire with a large temperature coefficient of resistance (such as platinum, nickel or copper wire) uniformly double-wound on a frame made of insulating material, or sprayed or printed with metal paste onto an insulating base plate. When a temperature gradient exists in the measured medium,
The measured temperature is the average temperature within the range where the sensing element is located.
Main features: wide measuring range, high measuring accuracy, long service life and convenient installation and use.
The types and tolerance classes of the assembled RTD are listed in Table 1
Table 1
| RTD types | Model | Graduation No. | R100/R0 | Measuring Range °C | ||
| Element | Measuring Range | Tolerance | ||||
| Assembled platinum RTD | WZPt10 | Pt10 | 1.3851 | Ceramic | -200~650 | Class A:±(0.15+0.2%lt1) Class B:±(0.3+0.5%lt1) |
| Glass | -200~500 | |||||
| WZPt100 | Pt100 | Mica | -200~420 | |||
| Thick film | ||||||
| Assembled copper RTD | WZCu50 | Cu50 | 1.4280 | -50~100 | ±(0.3+0.6%lt1) | |
| WZCu100 | Cu100 | |||||
● The outer diameter, length, material and thermal response time of the assembled RTD protection tube are listed in Table 2
| Protection Tube Dia. | LengthL | Material | Thermal Response TimeS |
| Ø12 | 225,250,350,400,450 550,650,900,1150 |
Carbon steel20#(-100~500℃) Stainless steel1Cr18Ni9Ti(-200~650℃) 0Cr18Ni12Mo2Ti(-200~650℃) Brass H62 (-100 to 200 °C) |
30~90 (Note: copper RTD Ø16:<180) |
| Ø16 | 300,350,450,500,650 900,1150,1650,2150 |
||
| Tapered tube Ø16 | 225,250,300,400 | 90~180 |
Table 2
The insulation resistance of the assembled platinum RTD at room temperature shall be not less than 100 MΩ
The insulation resistance of the assembled platinum RTD at room temperature shall be not less than 10 MΩ, with a test voltage of 100±50 V DC
Simplified type (without terminal head) Waterproof terminal head Flameproof terminal head
| Code | Name | Dimensions (mm) | Protection tube | ||||||||||
| M | H | S | D0 | Dia. (mm) | Material | Pressure MPa | |||||||
| 2 | Fixed thread | M27×2 | 32 | 32 | Ø40 | Ø16 | 1Cr18Ni9Ti or 20#Carbon steel |
≤10.0 | |||||
| ≤1.0 | |||||||||||||
| 6 | Tapered fixed thread | M33×2 | 33 | 36 | Ø48 | Tapered | 1Cr18Ni9Ti | ≤30.0 | |||||
| D1 | D2 | D0 | d0 | H | h | Dia. (mm) | Material | Pressure MPa | |||||
| 3 | Loose flange | Ø54 | Ø70 | / | Ø6 | Ø12orØ16 | TH10~26 | Atmospheric pressure | |||||
| 4 | Fixed flange | Ø65 | Ø95 | Ø45 | Ø14 | 16 | 3 | 1Cr18Ni9Ti or 20#Carbon steel |
≤6.0 | ||||
| ≤1.0 | |||||||||||||
The RTD element is one of the basic structures of a temperature measuring instrument and is divided into two categories: copper RTD elements and platinum RTD elements. Copper RTD elements cover a lower measuring range, while platinum RTDs cover a higher range with high accuracy and sensitivity.
The RTD element is a temperature sensor whose operating principle is that the resistance of the resistance wire changes under the effect of temperature. It can be used to measure temperatures in the range of -200 to 500 °C. Compared with thermocouples, its advantages include good electrical performance, a nearly linear temperature-resistance relationship, small deviation, and a deviation that remains negligible as service time increases.
The WZP series platinum RTD elements offer high accuracy, sensitivity and stability, with a compact structure, good reliability and short thermal response time. They are available as a series of products in multiple types and specifications, providing a new generation of quality products for the petroleum, chemical, power, light industry, machinery and scientific research sectors.
| RTD (Resistance Thermometer) Category |
Product model | Graduation No. | Measuring Range °C | Protection tube Material |
Specification | Specification | Specification | Specification | Thermal response Time τ0.5(S) |
| Dia. (mm) | Total length L mm |
Lo mm |
L1 mm |
||||||
| Single elementPlatinum RTD (Resistance Thermometer) Sensing elem. pcs |
WZP -010 |
Pt100 (BA1、 Ba2)* |
-200 ~420 |
Outer protection layer: 1Cr18Ni9Ti stainless steel sheet | Ø12 | 300 350 450 550 650 900 1150 1400 1650 2150 |
85 | 105 | <60 |
| Dual elementPlatinum RTD (Resistance Thermometer) Sensing elem. pcs |
WZP2 -010 |
||||||||
| Single elementPlatinum RTD (Resistance Thermometer) Sensing elem. pcs |
WZP -011 |
Ø8 | 300 350 450 550 |
65 |
80 |
<30 |
|||
| Dual platinum RTD sensing element | WZP2 -011 |
||||||||
| Platinum RTD sensing element | WZC- 010A |
Cu50 (G)* |
-50~ 100 | Copper tube | 300 350 450 550 650 900 1150 1400 1650 2150 |
<90 | |||
| WZP- 035S |
Pt100 | Stainless steel sheath | Ø6 | 535 | 35 | <5 | |||
| Copper RTD sensing element | WZC- 011 |
Cu50 (G)* |
Ø4 | 300 | 25 | <30 |
WZP-010、WZP-011
WZC-010A
WZP-035S、WZC-001
Note: ① Graduation numbers marked with “*” are supplied as special specifications,
②WZP-035S adopts the imported element WZP-014S, accuracy class: B.
| Product model | Graduation No. | Measuring Range °C | Accuracy Class | Protection Tube Material | Thermal Response Time τ0.5(S) |
| WZPM-018 | Pt10 Pt100 Pt1000 |
-200~+500 | B | Ceramic | ≤0.5 |
| WZPM-0110 | -50~+100 | 1Cr18Ni9Ti | ≤5 | ||
| WZPM-2012 | ≤10 |
| Product model | Graduation No. | Measuring Range °C | Accuracy Class | Thermowell material | Thermal Response Time τ0.5(S) |
| WZP-013S | Pt10 Pt100 Pt1000 |
-50~+150 | B | 1Cr18Ni9Ti | ≤2 |
| WZP-014S | -200~+500 | A、B | Ceramic | ≤0.5 | |
| WZP-015S | -50~+100 | B | 1Cr18Ni9Ti | ≤5 | |
| WZP-203S | |||||
| WZP-205S | 1Cr18Ni9Tii |
WZPM-018
WZPM-0110
WZPM-2012
WZP-013S
WZP-014S
WZP-015S
WZP-203S
WZPM-205S
Single element wiring Dual element wiring
| Name | Model | Graduation No. | Measuring Range °C | Specification | |
| D | L | ||||
| Single element PlatinumRTD (Resistance Thermometer) |
WZP-101 | Pt100 | -200~500 | Ø3 Ø4 Ø5 Ø6 |
310 360 410 460 510 560 |
| Dual element PlatinumRTD (Resistance Thermometer) |
WZP₂-101 | ||||
| Model | Graduation No. | Measuring Range °C | Thermal Response Time | Specification | |
| D | L | ||||
| WZP-130 WZP₂-130 |
Pt100 | -200~500 | <90S | Ø16 | 300 350 400 450 500 550 650 900 1150 1650 2150 |
| WZP-130G WZP₂-130G |
<24S | ||||
| WZP-131 WZP₂-131 |
<45S | Ø12 | |||
| WZP-131G W ZP-131G |
<24S | ||||
| WZC-130 | Cu50 CU100 | -50~100 | <120S | Ø16 | |
| W ZC-130G | <40S | ||||
| WZC-131 | <120S | Ø12 | |||
| W ZC-131G | <40S | ||||
2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement.
Waterproof, type 130 / 131 Waterproof, type 130G / 131G
| Model | Graduation No. | Measuring Range °C | Thermal Response Time | Specification | |
| D | L×l | ||||
| WZP-230 WZP₂-230 |
Pt100 | -200<500 | <90S | Ø16 | 300×150 350×200 400×250 450×300 500×350 550×400 650×500 900×750 1150×1000 1650×1500 2150×2000 |
| WZP-230G WZP₂-230G |
<24S | ||||
| WZP-231 WZP₂-231 |
<45S | Ø12 | |||
| WZP-231G WZP₂-231G |
<24S | ||||
| WZC-230 | Cu50 Cu100 |
-50~100 | <120S | Ø16 | |
| WZC-230G | <40S | ||||
| WZC-231 | <120S | Ø12 | |||
| WZC-231G | <40S | ||||
2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement
3) The nominal pressure is 10 MPa
Waterproof, type 230 / 231
| Model examples | Thread Spec. | |
| Code | M | |
| WZP-230 | M27×2 | |
| WZP-230A | A | G3/4 |
| WZP-230C | C | NPT3/4 |
| WZP-231G | M27×2 | |
| WZP-231GA | A | G3/4 |
| WZP-23GC | C | NPT3/4 |
Waterproof, type 230G / 231G
| Model | Graduation No. | Measuring Range °C | Thermal Response Time | Specification | |
| D | L×l | ||||
| WZP-330 WZP₂-330 |
Pt100 | -200~500 | <90S | Ø16 | 300×150 350×200 400×250 450×300 500×350 550×400 650×500 900×750 1150×1000 1650×1500 2150×2000 |
| WZP-330G WZP₂-330G |
<24S | ||||
| WZP-331 WZP₂-331 |
<45S | Ø12 | |||
| WZP-331G WZP₂-331G |
<24S | ||||
| WZC-330 | Cu50 Cu100 |
-50~100 | <120S | Ø16 | |
| WZC-330G | <40S | ||||
| WZC-331 | <120S | Ø12 | |||
| WZC-331G | <40S | ||||
2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement.
Waterproof, type 330G / 331G
| Model | Graduation No. | Measuring Range °C | Thermal Response Time | Specification | ||
| D | L×l | |||||
| WZP-430 WZP₂-430 |
Pt100 | -200~500 | <90S | Ø16 | 300×150 350×200 400×250 450×300 500×350 550×400 650×500 900×750 1150×1000 1650×1500 2150×2000 |
|
| WZP-430G WZP₂-430G |
<24S | |||||
| WZP-431 WZP₂-431 |
<45S | Ø12 | ||||
| WZP-431G WZP₂-431G |
<24S | |||||
| WZC-430 | Cu50 Cu100 |
-50<100 | <120S | Ø16 | ||
| WZC-430G | <40S | |||||
| WZC-431 | <120S | Ø12 | ||||
| WZC-431G | <40S | |||||
2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement,
3) The nominal pressure is 2.5 MPa.
| Model example | Flange spec. | ||||
| D | D1 | D2 | H | d | |
| WZP-430 | Ø105 | Ø75 | Ø55 | 16 | Ø16 |
| WZP-430G | |||||
| WZP-431 | |||||
| WZP-431G | |||||
Waterproof, type 430 / 431
Waterproof, type 430G / 431G
| Model | Graduation No. | Measuring Range °C | Thermal Response Time | Specification | |
| D | L×l | ||||
| WZP-630 WZP₂-630 |
Pt100 | -200~500 | <90S | Ø16 | 300×150 350×200 400×250 450×300 500×350 550×400 650×500 900×750 1150×1000 1650×1500 2150×2000 |
| WZP-630A WZP-630A |
<24S | ||||
| WZP-631 WZP₂-631 |
<45S | Ø12 | |||
| WZP-631A WZP₂-631A |
<24S | ||||
| WZC-630 | Cu50 Cu100 |
-50~100 | <120S | Ø16 | |
| WZC-630A | <40S | ||||
| WZC-631 | <120S | Ø12 | |||
| WZC-631A | <40S | ||||
2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement,
3) The protection tube bore adopts blind-hole technology,
4) The nominal pressure is ≤ 30 MPa.
| Model example | Thread Spec. | |
| Code | M | |
| WZP-630 | M33×2 | |
| NZP-630A | A | NPT1 |
| WZP-631 | M33×2 | |
| NZP-631A | A | NPT1 |
Waterproof, type 630 / 630A
Waterproof, type 630 / 630A
| Model | Graduation No. | Measuring Range °C | Thread Spec. | Specification | |
| D | L | ||||
| WZP-53 WZP₂-53 |
Pt100 | -200~500 | M20×1.5 | Ø3 Ø4 Ø5 Ø6 Ø8 |
245 270 295 345 395 445 545 645 745 899 1149 |
| WZP-53A WZP₂-53A |
NPT1/2 | ||||
| WZC-53 | Cu50 Cu100 |
-50~100 | M20×1.5 | Ø5 Ø6 Ø8 |
|
| WZC-53A | NPT1/2 | ||||
2) Unless otherwise agreed, L is for reference only; the insertion length of the thermocouple shall equal the U dimension of the thermowell,
3) See page 123 for thermowell types.
| Model | Graduation No. | Measuring Range °C | Thread Spec. | Specification | |
| D | L | ||||
| WZP-73 WZP₂-73 |
Pt100 | -200~500 | M20×1.5 | Ø3 Ø4 Ø5 Ø6 Ø8 |
245 270 295 345 395 445 545 645 745 899 1149 |
| WZP-73A WZP₂-73A |
NPT1/2 | ||||
| WZC-73 | Cu50 Cu100 |
-50~100 | M20×1.5 | Ø5 Ø6 Ø8 |
|
| WZC-73A | NPT1/2 | ||||
2) Unless otherwise agreed, L is for reference only; the insertion length of the thermocouple shall equal the U dimension of the thermowell,
3) See page 123 for thermowell types.
Waterproof, type 53 / 53A
| Code | M | D | D₁ | D₂ | d | h | H |
| 21A | M12×1.5 | Ø24 | Ø16 | Ø12 | Ø8 | 20 | 60 |
| 21B | M16×1.5 | ||||||
| 21C | M20×1.5 | Ø28 | |||||
| 21D | M27×2 | Ø39 | Ø28 | Ø24 | Ø20 | 35 | |
| 21E | M33×2 | Ø48 | Ø38 | Ø30 | Ø22 | 90 | |
| 21F | NPT1/2 | Ø28 | Ø16 | Ø12 | Ø8 | 20 | 60 |
| 21G | NPT3/4 | Ø39 | Ø28 | Ø24 | Ø20 | 35 | |
| 21H | NPT1 | Ø48 | Ø38 | Ø30 | Ø22 | 90 |
| Code | M | D | D₁ | d | h | H |
| 22A | M12×1.5 | Ø24 | Ø16 | Ø8 | 20 | 35 |
| 22B | M16×1.5 | |||||
| 22C | M20×1.5 | Ø28 | 45 | |||
| 22D | M27×2 | Ø39 | Ø28 | Ø20 | 35 | 60 |
| 22E | M33×2 | Ø48 | Ø38 | Ø22 | 90 | |
| 22F | NPT1/2 | Ø28 | Ø16 | Ø8 | 20 | 45 |
| 22G | NPT3/4 | Ø39 | Ø28 | Ø20 | 35 | 60 |
| 22H | NPT1 | Ø48 | Ø38 | Ø22 | 90 |
| Code | M | D | D₁ | R | h | H |
| 23A | M27×2 | Ø47 | Ø44 | 6 | 32 | 60 |
| 23B | M33×2 | Ø55 | Ø52 | 38 |