The WZ□ assembled RTD is used together with indicating instruments and can measure the temperature of liquids, gaseous media and solid surfaces in the range of -200 to 650 °C. It is widely used in aerospace, atomic energy, petroleum, chemical, power, textile, food and other sectors as well as in science and technology. The assembled RTD usually consists of a sensing element, an outer protection tube, a terminal head and mounting fittings.

Tel: 0512-57892201  Mobile: 13451695112

Key Features

  • Operating Principle
  • Main Technical Specifications
  • Insulation Resistance at Room Temperature
  • Typical terminal head types
  • Typical mounting types
  • Assembled RTDModel designation method
  • Sensing element
  • RTD (Resistance Thermometer)Element
  • Thin-film surface platinum RTD element
  • Inner-wound platinum RTD element
  • Wiring method
  • Sensing element
  • Without fixing devicePlatinumRTD (Resistance Thermometer)
  • : 1) Models 130 and 131 are waterproof, degree of protection IP55;
  • Fixed-thread platinum RTD
  • : 1) Models 230 and 231 are waterproof, degree of protection IP55;
  • Loose-flange platinum RTD
  • : 1) Models 330 and 331 are waterproof, degree of protection IP55;
  • Fixed-flange platinum RTD
  • : 1) Models 430 and 431 are waterproof, degree of protection IP55;
  • : Flanges can be supplied as agreed with the user
  • Fixed threadTaperedPlatinumRTD (Resistance Thermometer)
  • : 1) Models 630 and 631 are waterproof, degree of protection IP55;
  • Swivel unionPlatinumRTD (Resistance Thermometer)
  • : 1) Models 53 and 53A are waterproof, degree of protection IP55;
  • Straight unionPlatinumRTD (Resistance Thermometer)
  • : 1) Models 73 and 73A are waterproof, degree of protection IP55;

Technical Specifications

WZP₂—230Class A650×500B
Code Segment Meaning & Options Value in This Example
W Temperature instrument W
Z RTD (Resistance Thermometer) Z
P Sensing Element Material (P:Platinum C:Copper) P
₂ No. of Sensing Elements (Unmarked: single ₂: dual) ₂
2 Mounting Fitting (1:Without fixing device 2:Fixed thread 3:Loose flange 4:Fixed flange 5:Swivel union 6:Tapered fixed thread 7:Straight union) 2
3 Terminal Head Type (0:Simplified 2:Splash-proof 3:Waterproof 4:Flameproof) 3
0 Protection Tube O.D. (0:φ16mm 1:φ12mm) 0
Class A Accuracy Class (Class A / Class B) Class A
650×500 Total Length × Insertion Length 650×500
B Protection Tube Material (B:1Cr18Ni9Ti) B

The RTD is designed and manufactured on the principle that the resistance of a substance changes with temperature. The sensing part of an RTD is made of metal wire with a large temperature coefficient of resistance (such as platinum, nickel or copper wire) uniformly double-wound on a frame made of insulating material, or sprayed or printed with metal paste onto an insulating base plate. When a temperature gradient exists in the measured medium,

The measured temperature is the average temperature within the range where the sensing element is located.

Main features: wide measuring range, high measuring accuracy, long service life and convenient installation and use.

The types and tolerance classes of the assembled RTD are listed in Table 1

Table 1

RTD types Model Graduation No. R100/R0 Measuring Range °C
Element Measuring Range Tolerance
Assembled platinum RTD WZPt10 Pt10 1.3851 Ceramic -200~650 Class A:±(0.15+0.2%lt1)
Class B:±(0.3+0.5%lt1)
Glass -200~500
WZPt100 Pt100 Mica -200~420
Thick film
Assembled copper RTD WZCu50 Cu50 1.4280 -50~100 ±(0.3+0.6%lt1)
WZCu100 Cu100

● The outer diameter, length, material and thermal response time of the assembled RTD protection tube are listed in Table 2

Protection Tube Dia. LengthL Material Thermal Response TimeS
Ø12 225,250,350,400,450
550,650,900,1150
Carbon steel20#(-100~500℃)
Stainless steel1Cr18Ni9Ti(-200~650℃)
0Cr18Ni12Mo2Ti(-200~650℃)
Brass H62 (-100 to 200 °C)
30~90
(Note: copper RTD Ø16:<180)
Ø16 300,350,450,500,650
900,1150,1650,2150
Tapered tube Ø16 225,250,300,400 90~180

Table 2

The insulation resistance of the assembled platinum RTD at room temperature shall be not less than 100 MΩ

The insulation resistance of the assembled platinum RTD at room temperature shall be not less than 10 MΩ, with a test voltage of 100±50 V DC

Simplified type (without terminal head) Waterproof terminal head Flameproof terminal head

Code Name Dimensions (mm) Protection tube
M H S D0 Dia. (mm) Material Pressure MPa
2 Fixed thread M27×2 32 32 Ø40 Ø16 1Cr18Ni9Ti
or
20#Carbon steel
≤10.0
≤1.0
6 Tapered fixed thread M33×2 33 36 Ø48 Tapered 1Cr18Ni9Ti ≤30.0
D1 D2 D0 d0 H h Dia. (mm) Material Pressure MPa
3 Loose flange Ø54 Ø70 / Ø6 Ø12orØ16 TH10~26 Atmospheric pressure
4 Fixed flange Ø65 Ø95 Ø45 Ø14 16 3 1Cr18Ni9Ti
or
20#Carbon steel
≤6.0
≤1.0

The RTD element is one of the basic structures of a temperature measuring instrument and is divided into two categories: copper RTD elements and platinum RTD elements. Copper RTD elements cover a lower measuring range, while platinum RTDs cover a higher range with high accuracy and sensitivity.

The RTD element is a temperature sensor whose operating principle is that the resistance of the resistance wire changes under the effect of temperature. It can be used to measure temperatures in the range of -200 to 500 °C. Compared with thermocouples, its advantages include good electrical performance, a nearly linear temperature-resistance relationship, small deviation, and a deviation that remains negligible as service time increases.

The WZP series platinum RTD elements offer high accuracy, sensitivity and stability, with a compact structure, good reliability and short thermal response time. They are available as a series of products in multiple types and specifications, providing a new generation of quality products for the petroleum, chemical, power, light industry, machinery and scientific research sectors.

RTD (Resistance Thermometer)
Category
Product model Graduation No. Measuring Range °C Protection tube
Material
Specification Specification Specification Specification Thermal response
Time
τ0.5(S)
Dia. (mm) Total length L
mm
Lo
mm
L1
mm
Single elementPlatinum
RTD (Resistance Thermometer)
Sensing elem.
pcs
WZP
-010
Pt100
(BA1、
Ba2)*
-200
~420
Outer protection layer: 1Cr18Ni9Ti stainless steel sheet Ø12 300
350
450
550
650
900
1150
1400
1650
2150
85 105 <60
Dual elementPlatinum RTD (Resistance Thermometer)
Sensing elem. pcs
WZP2
-010
Single elementPlatinum
RTD (Resistance Thermometer)
Sensing elem.
pcs
WZP
-011
Ø8 300
350
450
550

65

80

<30

Dual platinum RTD sensing element WZP2
-011
Platinum RTD sensing element WZC-
010A
Cu50
(G)*
-50~ 100 Copper tube 300
350
450
550
650
900
1150
1400
1650
2150
<90
WZP-
035S
Pt100 Stainless steel sheath Ø6 535 35 <5
Copper RTD sensing element WZC-
011
Cu50
(G)*
Ø4 300 25 <30

WZP-010、WZP-011

WZC-010A

WZP-035S、WZC-001

Note: ① Graduation numbers marked with “*” are supplied as special specifications,

②WZP-035S adopts the imported element WZP-014S, accuracy class: B.

Product model Graduation No. Measuring Range °C Accuracy Class Protection Tube Material Thermal Response Time
τ0.5(S)
WZPM-018 Pt10
Pt100
Pt1000
-200~+500 B Ceramic ≤0.5
WZPM-0110 -50~+100 1Cr18Ni9Ti ≤5
WZPM-2012 ≤10
Product model Graduation No. Measuring Range °C Accuracy Class Thermowell material Thermal Response Time
τ0.5(S)
WZP-013S Pt10
Pt100
Pt1000
-50~+150 B 1Cr18Ni9Ti ≤2
WZP-014S -200~+500 A、B Ceramic ≤0.5
WZP-015S -50~+100 B 1Cr18Ni9Ti ≤5
WZP-203S
WZP-205S 1Cr18Ni9Tii

WZPM-018

WZPM-0110

WZPM-2012

WZP-013S

WZP-014S

WZP-015S

WZP-203S

WZPM-205S

Single element wiring Dual element wiring

Name Model Graduation No. Measuring Range °C Specification
D L
Single element
PlatinumRTD (Resistance Thermometer)
WZP-101 Pt100 -200~500 Ø3
Ø4
Ø5
Ø6
310
360
410
460
510
560
Dual element
PlatinumRTD (Resistance Thermometer)
WZP₂-101
Model Graduation No. Measuring Range °C Thermal Response Time Specification
D L
WZP-130
WZP₂-130
Pt100 -200~500 <90S Ø16 300
350
400
450
500
550
650
900
1150
1650
2150
WZP-130G
WZP₂-130G
<24S
WZP-131
WZP₂-131
<45S Ø12
WZP-131G
W ZP-131G
<24S
WZC-130 Cu50 CU100 -50~100 <120S Ø16
W ZC-130G <40S
WZC-131 <120S Ø12
W ZC-131G <40S

2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement.

Waterproof, type 130 / 131 Waterproof, type 130G / 131G

Model Graduation No. Measuring Range °C Thermal Response Time Specification
D L×l
WZP-230
WZP₂-230
Pt100 -200<500 <90S Ø16 300×150
350×200
400×250
450×300
500×350
550×400
650×500
900×750
1150×1000
1650×1500
2150×2000
WZP-230G
WZP₂-230G
<24S
WZP-231
WZP₂-231
<45S Ø12
WZP-231G
WZP₂-231G
<24S
WZC-230 Cu50
Cu100
-50~100 <120S Ø16
WZC-230G <40S
WZC-231 <120S Ø12
WZC-231G <40S

2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement

3) The nominal pressure is 10 MPa

Waterproof, type 230 / 231

Model examples Thread Spec.
Code M
WZP-230 M27×2
WZP-230A A G3/4
WZP-230C C NPT3/4
WZP-231G M27×2
WZP-231GA A G3/4
WZP-23GC C NPT3/4

Waterproof, type 230G / 231G

Model Graduation No. Measuring Range °C Thermal Response Time Specification
D L×l
WZP-330
WZP₂-330
Pt100 -200~500 <90S Ø16 300×150
350×200
400×250
450×300
500×350
550×400
650×500
900×750
1150×1000
1650×1500
2150×2000
WZP-330G
WZP₂-330G
<24S
WZP-331
WZP₂-331
<45S Ø12
WZP-331G
WZP₂-331G
<24S
WZC-330 Cu50
Cu100
-50~100 <120S Ø16
WZC-330G <40S
WZC-331 <120S Ø12
WZC-331G <40S

2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement.

Waterproof, type 330G / 331G

Model Graduation No. Measuring Range °C Thermal Response Time Specification
D L×l
WZP-430
WZP₂-430
Pt100 -200~500 <90S Ø16 300×150
350×200
400×250
450×300
500×350
550×400
650×500
900×750
1150×1000
1650×1500
2150×2000
WZP-430G
WZP₂-430G
<24S
WZP-431
WZP₂-431
<45S Ø12
WZP-431G
WZP₂-431G
<24S
WZC-430 Cu50
Cu100
-50<100 <120S Ø16
WZC-430G <40S
WZC-431 <120S Ø12
WZC-431G <40S

2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement,

3) The nominal pressure is 2.5 MPa.

Model example Flange spec.
D D1 D2 H d
WZP-430 Ø105 Ø75 Ø55 16 Ø16
WZP-430G
WZP-431
WZP-431G

Waterproof, type 430 / 431

Waterproof, type 430G / 431G

Model Graduation No. Measuring Range °C Thermal Response Time Specification
D L×l
WZP-630
WZP₂-630
Pt100 -200~500 <90S Ø16 300×150
350×200
400×250
450×300
500×350
550×400
650×500
900×750
1150×1000
1650×1500
2150×2000
WZP-630A
WZP-630A
<24S
WZP-631
WZP₂-631
<45S Ø12
WZP-631A
WZP₂-631A
<24S
WZC-630 Cu50
Cu100
-50~100 <120S Ø16
WZC-630A <40S
WZC-631 <120S Ø12
WZC-631A <40S

2) The protection tube material is 1Cr18Ni9Ti; other materials are supplied per agreement,

3) The protection tube bore adopts blind-hole technology,

4) The nominal pressure is ≤ 30 MPa.

Model example Thread Spec.
Code M
WZP-630 M33×2
NZP-630A A NPT1
WZP-631 M33×2
NZP-631A A NPT1

Waterproof, type 630 / 630A

Waterproof, type 630 / 630A

Model Graduation No. Measuring Range °C Thread Spec. Specification
D L
WZP-53
WZP₂-53
Pt100 -200~500 M20×1.5 Ø3
Ø4
Ø5
Ø6
Ø8
245
270
295
345
395
445
545
645
745
899
1149
WZP-53A
WZP₂-53A
NPT1/2
WZC-53 Cu50
Cu100
-50~100 M20×1.5 Ø5
Ø6
Ø8
WZC-53A NPT1/2

2) Unless otherwise agreed, L is for reference only; the insertion length of the thermocouple shall equal the U dimension of the thermowell,

3) See page 123 for thermowell types.

Model Graduation No. Measuring Range °C Thread Spec. Specification
D L
WZP-73
WZP₂-73
Pt100 -200~500 M20×1.5 Ø3
Ø4
Ø5
Ø6
Ø8
245
270
295
345
395
445
545
645
745
899
1149
WZP-73A
WZP₂-73A
NPT1/2
WZC-73 Cu50
Cu100
-50~100 M20×1.5 Ø5
Ø6
Ø8
WZC-73A NPT1/2

2) Unless otherwise agreed, L is for reference only; the insertion length of the thermocouple shall equal the U dimension of the thermowell,

3) See page 123 for thermowell types.

Waterproof, type 53 / 53A

RTD installation diagram

Vertical pipe installation

Curved pipe installation

Inclined pipe installation method

Flange installation method

Straight connection head specification

Code M D D₁ D₂ d h H
21A M12×1.5 Ø24 Ø16 Ø12 Ø8 20 60
21B M16×1.5
21C M20×1.5 Ø28
21D M27×2 Ø39 Ø28 Ø24 Ø20 35
21E M33×2 Ø48 Ø38 Ø30 Ø22 90
21F NPT1/2 Ø28 Ø16 Ø12 Ø8 20 60
21G NPT3/4 Ø39 Ø28 Ø24 Ø20 35
21H NPT1 Ø48 Ø38 Ø30 Ø22 90
Code M D D₁ d h H
22A M12×1.5 Ø24 Ø16 Ø8 20 35
22B M16×1.5
22C M20×1.5 Ø28 45
22D M27×2 Ø39 Ø28 Ø20 35 60
22E M33×2 Ø48 Ø38 Ø22 90
22F NPT1/2 Ø28 Ø16 Ø8 20 45
22G NPT3/4 Ø39 Ø28 Ø20 35 60
22H NPT1 Ø48 Ø38 Ø22 90
Code M D D₁ R h H
23A M27×2 Ø47 Ø44 6 32 60
23B M33×2 Ø55 Ø52 38

Ordering & Inquiry

For selection guidance, specification confirmation or quotation, please call 0512-57892201, Mobile 13451695112, or submit an online order. Suzhou Dingluxuan Sensor Technology Co., Ltd. provides a complete matching service from temperature sensing elements to complementary ceramic insulation parts.

Model:
Select attributes above to filter available models

To order this product or get selection guidance, please call +86 512-57892201 or submit an online order.

Inquire About This Product → Back to Products

Dingluxuan Sensor Technology

Design, manufacturing and sales of temperature, pressure and humidity sensors, instruments and ceramic products — delivering integrated temperature-measurement and control solutions.

Products

Products

Applications

Applications

Contact Us

Contact
No. 828 Xueyuan Road, Bacheng Town, Kunshan City, Jiangsu, China
Tel
0512-57892201
Mobile: 13451695112
Email: yanghui@dingluxuan.com
Copyright©2017-2026  Suzhou Dingluxuan Sensor Technology Co., Ltd.   苏ICP备17068273号-1
中文EN
中文EN
×

Need help with selection or a quote?

Send us your operating conditions and get model recommendations plus a quote within 1 business day.

Inquire Online → Or call +86 512-57892201