Type keywords to search pages, products, standards and articles
Special thermocouple (RTD)
Applications Operating Principle
Tel: 0512-57892201 Mobile: 13451695112
Special structural design, suitable for different applications. It can directly measure liquids, steam and gaseous media as well as solid surfaces within -200 °C to 1600 °C.
EC584
EC751
JB/T5582-1991
Generally refers to the static external pressure that the protection tube can withstand at room temperature without rupture. The permissible working pressure depends not only on the protection tube material, diameter and wall thickness, but also on its structure, installation method and the flow velocity and type of the measured medium.
The electrodes of a thermocouple are made of two different conductor materials. When a temperature difference exists between the measuring junction and the reference junction, a thermoelectric EMF is generated, and the indicating instrument displays the temperature value corresponding to that EMF.
The RTD measures temperature by means of the characteristic that the resistance of a substance changes with temperature. When the resistance value changes, the indicating instrument displays the temperature value corresponding to that resistance.
For thermocouples, at an ambient temperature of 20±15 °C, relative humidity not exceeding 80%, and a test voltage of 500±50 V (DC), the insulation resistance between the electrode and the outer sheath shall be ≥ 1000 MΩ·m. For RTDs, at an ambient temperature of 15–35 °C, relative humidity not exceeding 80%, and a test voltage of 10–100 V (DC), the insulation resistance between the electrode and the outer sheath shall be ≥ 100 MΩ.
| Model | Graduation No. | Tolerance Class | |||
| I | II | ||||
| Tolerance value | Measuring Range °C | Tolerance value | Measuring Range °C | ||
| WRN | K | ±1.5℃ | -40~375 | ±2.5℃ | -40~333 |
| ±0.004 ItI | 375~1000 | ±0.0075ItI | 333~1200 | ||
| WRE | E | ±1.5℃ | -40~375 | ±2.5℃ | -40~333 |
| ±0.004 ItI | 375~800 | ±0.0075Itl | 333~900 | ||
| WRP | S | ±1℃ | 0~1100 | ±2.5℃ | 0~600 |
| ±[1+0.003(t-1100)] | 1100~1600 | ±0.0025Itl | 600~1600 | ||
| WRQ | R | ±1℃ | 0~1100 | ±2.5℃ | 0~1100 |
| ±[1+0.003(t-1100)] | 1100~1600 | ±0.0025ItI | 1100~1600 | ||
| WRR | B | Class I | Class I | Class I | |
| Class I | 600~1700 | ||||
| Model | Graduation No. | Measuring Range °C | Accuracy Class | Permissible deviation |
| WZP | Pt100 | -200~500 | A | ±(0.15+0.002 ItI) |
| B | ±(0.30+0.005 ItI) | |||
| WZC | Cu50 Cu100 |
50~100 | Class I | ±(0.30+0.006 ItI) |
For selection guidance, specification confirmation or quotation, please call 0512-57892201, Mobile 13451695112, or submit an online order. Suzhou Dingluxuan Sensor Technology Co., Ltd. provides a complete matching service from temperature sensing elements to complementary ceramic insulation parts.
No selectable data could be extracted for this product. Please check “Product Specifications” or contact us for guidance.
To order this product or get selection guidance, please call +86 512-57892201 or submit an online order.