WR□T-11 MI thermocouple for boilers and clamps
The WR□T-11 boiler wall MI thermocouple uses an Ø4 MI thermocouple as the sensing element, while the WR□T-11M boiler wall MI thermocouple uses an Ø3–Ø6 MI thermocouple. The hot junction is firmly attached to a stainless steel sensing plate with different curved surfaces, making it suitable for temperature measurement on boiler walls, pipe walls and cylindrical surfaces. The WR□T-11G clamp-type thermocouple is specially designed for temperature measurement on cylindrical surfaces.
Tel: 0512-57892201 Mobile: 13451695112
| Name | Model | Graduation No. | Measuring Range ℃ |
Tolerance Class | MI dia. | Measuring junction | LengthL mm |
||
| Type & response time | Curved surface Radius |
Mounting method | |||||||
| Furnace wall thermocouple | WRNT-11 | K | 0~800 | Class I
or Class II |
Ø4 | Grounded (shell-contact):≤0.8s Insulated:≤2.5s |
R29 R100 | Welded or screw-fixed | 3000 4000 5000 6000 7000 8000 |
| WRMT-11 | N | ||||||||
| WRET-11 | E | 0~600 | |||||||
| WRNT-11M | K | 0~800 | Ø3~Ø6 | Ø3~Ø4.5 Grounded (shell-contact):≤1s Insulated:≤3s Ø5~Ø6 Grounded (shell-contact):≤2s Insulated:≤6s |
Welding |
3000 5000 8000 10000 15000 20000 |
|||
| WRMT-11M | N | ||||||||
| WRET-11M | E | 0~600 | |||||||
|
Clamp |
WRNT-11G | K | 0~800 | Ø3~Ø8 | Grounded (shell-contact):≤4s Insulated:≤8s |
Ø58 Ø100 |
Class I | 300 400 500 1000 1200 1500 |
|
| WRMT-11G | N | ||||||||
| WRET-11G | E | 0~600 | |||||||